Back to Search
Start Over
USPIO-enhanced MR angiography of arteriovenous fistulas in patients with renal failure.
- Source :
-
Radiology [Radiology] 2012 Nov; Vol. 265 (2), pp. 584-90. Date of Electronic Publication: 2012 Aug 08. - Publication Year :
- 2012
-
Abstract
- Purpose: To determine the feasibility of using ferumoxytol-enhanced magnetic resonance (MR) angiography to depict the vasculature of hemodialysis fistulas and improve image quality compared with nonenhanced time-of-flight (TOF) MR angiography.<br />Materials and Methods: The study was institutional review board approved and was in compliance with HIPAA regulations. All participants provided written informed consent. TOF and first-pass ferumoxytol-enhanced MR angiography were performed in 10 patients with upper extremity autogenous fistulas. Ferumoxytol was administered as a bolus solution containing 430 μmol of elemental iron. A qualitative comparison was performed on maximum intensity projection images. Lumen depiction was evaluated by using a five-point scale. The uniformity of intraluminal signal intensity was measured as the ratio between the mean signal intensity of the entirety of the imaged fistula and its standard deviation. The contrast-to-noise ratio (CNR) between intraluminal signal and adjacent tissue was evaluated as a function of image acquisition time. Lumen depiction scores, luminal signal heterogeneity, and CNR efficiency were compared between TOF and ferumoxytol-enhanced MR angiography by using a Wilcoxon-Mann-Whitney test.<br />Results: Flow artifacts were greatly reduced by the use of ferumoxytol-enhanced MR angiography. Ferumoxytol-enhanced MR angiography had significantly better performance than TOF MR angiography as measured with the following: lumen depiction scores in all segments (mean, 4.7±0.1 [standard error of the mean]; vs 3.0±0.3 for arterial inflow, 4.1±0.3 vs 1.9±0.3 for arterial outflow, 3.7±0.3 vs 1.8±0.2 for anastomosis, and 4.5±0.2 vs 2.1±0.2 for venous outflow; P<.001), intraluminal signal homogeneity (0.3±0.02 vs 0.4±0.06, P=.005), and CNR efficiency in the venous outflow (5.1±0.6 vs 2.5±0.4, P=.01).<br />Conclusion: This study demonstrates the feasibility of using ferumoxytol-enhanced MR angiography in imaging hemodialysis fistulas with consistently superior image quality compared with nonenhanced TOF MR angiography.<br /> (© RSNA, 2012)
- Subjects :
- Contrast Media
Female
Humans
Male
Reproducibility of Results
Sensitivity and Specificity
Anastomosis, Surgical
Arteriovenous Anastomosis pathology
Dextrans
Image Enhancement methods
Magnetic Resonance Angiography methods
Magnetite Nanoparticles
Renal Insufficiency pathology
Renal Insufficiency surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1527-1315
- Volume :
- 265
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 22875796
- Full Text :
- https://doi.org/10.1148/radiol.12112694