Back to Search
Start Over
Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling.
Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling.
- Source :
-
Lasers in medical science [Lasers Med Sci] 2013 May; Vol. 28 (3), pp. 833-44. Date of Electronic Publication: 2012 Jul 27. - Publication Year :
- 2013
-
Abstract
- Endovenous laser treatment (ELT) has been proposed as an alternative in the treatment of reflux of the great saphenous vein. Before the procedure, peri-saphenous subcutaneous tumescent saline solution infiltration is usually performed. However, diffusion of this tumescent fluid is rapidly observed and can potentially reduce the efficacy as a heat sink. External skin cooling with cold air was proposed as an alternative solution. The objective of this study is to compare endovenous laser treatment without and with air cooling by realistic numerical simulations. An optical-thermal damage model was formulated and implemented using finite element modeling. The general model simulated light distribution using the diffusion approximation of the transport theory, temperature rise using the bioheat equation, and laser-induced injury using the Arrhenius damage model. Parameters, used in clinical procedures, were considered: power, 15 W; pulse duration, 1 s; fiber pull back, 3-mm increments every second; cold air applied in continuous mode during ELT; and no tumescent anesthesia. Simulations were performed for vein locations at 5, 10, and 15 mm in depth, with and without air cooling. For a vein located at 15 mm in depth, no significant difference was observed with and without cooling. For a vein located at 10 mm in depth, surface temperature increase up to 45 °C is observed without cooling. For a vein located at 5 mm, without cooling, temperature increase leads to irreversible damage of dermis and epidermis. Conversely, with air cooling, surface temperature reaches a maximum of 38 °C in accordance with recordings performed on patients. ELT of the incompetent great saphenous vein with external air cooling system is a promising therapy technique. Use of cold air on the skin continuously flowing in the area of laser shot decreased significantly the heat extent and the thermal damage in the perivenous tissues and the skin.
- Subjects :
- Computer Simulation
Cryotherapy methods
Endovascular Procedures adverse effects
Finite Element Analysis
Hot Temperature adverse effects
Humans
Laser Therapy adverse effects
Models, Biological
Saphenous Vein injuries
Skin Temperature
Endovascular Procedures methods
Laser Therapy methods
Saphenous Vein surgery
Venous Insufficiency surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1435-604X
- Volume :
- 28
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Lasers in medical science
- Publication Type :
- Academic Journal
- Accession number :
- 22836189
- Full Text :
- https://doi.org/10.1007/s10103-012-1141-0