Back to Search
Start Over
European survey on efficacy and safety of duty-cycled radiofrequency ablation for atrial fibrillation.
- Source :
-
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2012 Dec; Vol. 14 (12), pp. 1700-7. Date of Electronic Publication: 2012 Jul 06. - Publication Year :
- 2012
-
Abstract
- Aims: Duty-cycled radiofrequency ablation (RFA) has been used for atrial fibrillation (AF) for around 5 years, but large-scale data are scarce. The purpose of this survey was to report the outcome of the technique.<br />Methods and Results: A survey was conducted among 20 centres from seven European countries including 2748 patients (2128 with paroxysmal and 620 with persistent AF). In paroxysmal AF an overall success rate of 82% [median 80%, interquartile range (IQR) 74-90%], a first procedure success rate of 72% [median 74% (IQR 59-83%)], and a success of antiarrhythmic medication of 59% [median 60% (IQR 39-72%)] was reported. In persistent AF, success rates were significantly lower with 70% [median 74% (IQR 60-92%)]; P = 0.05) as well as the first procedure success rate of 58% [median 55% (IQR 47-81%)]; P = 0.001). The overall success rate was similar among higher and lower volume centres and were not dependent on the duration of experience with duty-cycled RFA (r = -0.08, P = 0.72). Complications were observed in 108 (3.9%) patients, including 31 (1.1%) with symptomatic transient ischaemic attack or stroke, which had the same incidence in paroxysmal and persistent AF (1.1 vs. 1.1%) and was unrelated to the case load (r = 0.24, P = 0.15), bridging anticoagulation to low molecular heparin, routine administration of heparin over the long sheath, whether a transoesophageal echocardiogram was performed in every patient or not and average procedure times.<br />Conclusion: Duty-cycled RFA has a self-reported success and complication rate similar to conventional RFA. After technical modifications a prospective registry with controlled data monitoring should be conducted to assess outcome.
Details
- Language :
- English
- ISSN :
- 1532-2092
- Volume :
- 14
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 22772054
- Full Text :
- https://doi.org/10.1093/europace/eus188