Back to Search Start Over

Simultaneous clarification of Escherichia coli culture and purification of extracellularly produced penicillin G acylase using tangential flow filtration and anion-exchange membrane chromatography (TFF-AEMC).

Authors :
Orr V
Scharer J
Moo-Young M
Honeyman CH
Fenner D
Crossley L
Suen SY
Chou CP
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2012 Jul 01; Vol. 900, pp. 71-8. Date of Electronic Publication: 2012 Jun 07.
Publication Year :
2012

Abstract

Downstream purification often represents the most cost-intensive step in the manufacturing of recombinant proteins since conventional purification processes are lengthy, technically complicated, and time-consuming. To address this issue, herein we demonstrated the simultaneous clarification and purification of the extracellularly produced recombinant protein by Escherichia coli using an integrated system of tangential flow filtration and anion exchange membrane chromatography (TFF-AEMC). After cultivation in a bench-top bioreactor with 1L working volume using the developed host/vector system for high-level expression and effective secretion of recombinant penicillin G acylase (PAC), the whole culture broth was applied directly to the established system. One-step purification of recombinant PAC was achieved based on the dual nature of membrane chromatography (i.e. microfiltration-sized pores and anion-exchange chemistry) and cross-flow operations. Most contaminant proteins in the extracellular medium were captured by the anion-exchange membrane and cells remained in the retentate, whereas extracellular PAC was purified and collected in the filtrate. The batch time for both cultivation and purification was less than 24h and recombinant PAC with high purity (19 U/mg), yield (72% recovery), and productivity (41 mg of purified PAC per liter of culture) was obtained. Due to the nature of the non-selective protein secretion system and the versatility of ion-exchange membrane chromatography, the developed system can be widely applied for effective production and purification of recombinant proteins.<br /> (Copyright © 2012 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
900
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
22709629
Full Text :
https://doi.org/10.1016/j.jchromb.2012.05.039