Back to Search
Start Over
A sensitive assay for palytoxins, ovatoxins and ostreocins using LC-MS/MS analysis of cleavage fragments from micro-scale oxidation.
- Source :
-
Toxicon : official journal of the International Society on Toxinology [Toxicon] 2012 Oct; Vol. 60 (5), pp. 810-20. Date of Electronic Publication: 2012 May 31. - Publication Year :
- 2012
-
Abstract
- Palytoxin is a highly toxic non-proteinaceous marine natural product that can pass through the food chain and result in human illnesses. A recent review by the European Food Safety Authority concluded that palytoxin requires regulation in seafood and a limit of 30 μg kg⁻¹ for shellfish flesh was suggested. Current methods based on LC-MS detection of intact palytoxins do not have sufficient sensitivity to enforce this limit for palytoxin. To improve sensitivity for trace analysis, a novel screen approach has been developed that uses LC-MS/MS analysis of substructures generated by oxidative cleavage of vicinal diol groups present in the intact toxin. Oxidation of palytoxins, ovatoxins or ostreocins using periodic acid generates two nitrogen-containing aldehyde fragments; an amino aldehyde common to these toxins, and an amide aldehyde that may vary depending on toxin type. Conditions for micro-scale oxidation of palytoxin were optimised, which include a novel SPE cleanup and on-column oxidation step. Rapid analysis of cleavage fragments was established using LC-MS/MS. Linear calibrations were established for the amino aldehyde from a palytoxin reference standard, which is suitable for all known palytoxin-like compounds, and for the confirmatory amide aldehydes of palytoxin and ostreocin-D. Palytoxin recoveries (at 10 μg kg⁻¹) from shellfish and fish tissues were 114-119% (as amine aldehyde) and 90-115% (as amide aldehyde) with RSDs for both of ≤ 18% (all tissues, n = 12). The method LOD was determined to be approximately 1 ng mL⁻¹ and the LOQ 4 ng mL⁻¹, which corresponds to 10 μg kg⁻¹ in tissue (flesh of shellfish or fish). The method has potential for use in research and is sufficiently sensitive for regulatory testing, should it be required.<br /> (Copyright © 2012. Published by Elsevier Ltd.)
Details
- Language :
- English
- ISSN :
- 1879-3150
- Volume :
- 60
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Toxicon : official journal of the International Society on Toxinology
- Publication Type :
- Academic Journal
- Accession number :
- 22659542
- Full Text :
- https://doi.org/10.1016/j.toxicon.2012.05.024