Back to Search Start Over

Modifying the STM tip for the ' ultimate ' imaging of the Si(111)-7×7 surface and metal-supported molecules.

Authors :
Wang YL
Cheng ZH
Deng ZT
Guo HM
Du SX
Gao HJ
Source :
Chimia [Chimia (Aarau)] 2012; Vol. 66 (1-2), pp. 31-7.
Publication Year :
2012

Abstract

We report on high-resolution STM measurements with modified probe tips. First, both the rest atoms and adatoms of a Si(111)-7×7 surface are observed simultaneously. The visibility of rest atoms is dependent upon the sample bias voltage (less than -0.7 V) and is enhanced by sharpening the tip, which is rationalized by first-principles calculations. Second, a tip with a perylene molecule adsorbed at its apex is used to discriminate the molecular states and the metal states of the underlying Ag(110) surface, which is attributable to a mismatch between the energy levels of the functionalized tip and the adsorbates on silver. Lastly, high-resolution images of iron phthalocyanine (FePc) and zinc phthalocyanine (ZnPc) molecules on Au(111) are obtained by using an O(2)-terminated tip, and the images reveal rich intramolecular features arising from molecular orbitals that are not observed when using clean metallic tips.

Details

Language :
English
ISSN :
0009-4293
Volume :
66
Issue :
1-2
Database :
MEDLINE
Journal :
Chimia
Publication Type :
Academic Journal
Accession number :
22546188
Full Text :
https://doi.org/10.2533/chimia.2012.31