Back to Search Start Over

Municipal wastewater treatment by biofiltration: comparisons of various treatment layouts. Part 2: assessment of the operating costs in optimal conditions.

Authors :
Rocher V
Paffoni C
Gonçalves A
Azimi S
Pauss A
Source :
Water science and technology : a journal of the International Association on Water Pollution Research [Water Sci Technol] 2012; Vol. 65 (9), pp. 1713-9.
Publication Year :
2012

Abstract

This work aims to compare the operation costs (energy, reagents, waste management) for the three layouts usually used in wastewater treatment plants incorporating biofilters, using technical and economical data acquired during 10 years of operation of a Parisian plant (Seine Centre, 240,000 m(3) d(-1) -800,000 equivalent inhabitants). The final objective is to establish general economical data and tendencies that can be translated from our study to any biofiltration plant. Our results evidenced the savings achieved through the treatment process combining upstream and downstream denitrification. To use this layout reduced the operating costs by some 10% as compared with conventional processing only comprising downstream denitrification. Operating costs were respectively estimated at 37 and 34 €/1,000 m(3) for downstream denitrification and combining upstream and downstream denitrification layouts.

Details

Language :
English
ISSN :
0273-1223
Volume :
65
Issue :
9
Database :
MEDLINE
Journal :
Water science and technology : a journal of the International Association on Water Pollution Research
Publication Type :
Academic Journal
Accession number :
22508137
Full Text :
https://doi.org/10.2166/wst.2012.929