The effects of arm elevation on the 3-dimensional acromiohumeral distance: a biplane fluoroscopy study with normative data.
- Source :
-
Journal of shoulder and elbow surgery [J Shoulder Elbow Surg] 2012 Nov; Vol. 21 (11), pp. 1593-600. Date of Electronic Publication: 2012 Feb 22. - Publication Year :
- 2012
-
Abstract
- Hypothesis and Background: Narrowing of the subacromial space has been implicated in several shoulder pathologies. However, the location of the minimum distance points during clinical testing has not been defined. We sought to measure the in vivo minimum distance and location of the minimum distance points on the acromion and proximal humerus during arm elevation.<br />Methods: Eight healthy male subjects (mean age, 30 years) underwent a dynamic in vivo biplane fluoroscopy assessment of scaption and forward elevation. For each frame, the 3-dimensional position and orientation of the humerus and scapula were determined, and the acromiohumeral distance (AHD) was measured as the shortest distance between the acromion and proximal humerus.<br />Results: The minimum AHD was 2.6 ± 0.8 mm during scaption and 1.8 ± 1.2 mm during forward flexion at elevation angles of 83° ± 13° and 97° ± 23°, respectively. The minimum distance point was located on the articular surface of the humeral head from the neutral arm position until 34° ± 8° for scaption and 36° ± 6° for forward flexion. Upon further elevation, the minimum distance point was located within the footprint of the supraspinatus muscle until 72° ± 12° for scaption and 65° ± 8° for forward flexion. At greater elevation angles, the minimum distance points were between the acromion and the proximal humeral shaft, distal from the greater tuberosity.<br />Conclusions: The shortest AHD was at approximately 90° of arm elevation. The AHD was no longer measured intra-articularly or within the supraspinatus footprint above approximately 70° of arm elevation.<br /> (Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.)
- Subjects :
- Adult
Arm physiopathology
Biomechanical Phenomena
Humans
Male
Range of Motion, Articular
Reference Values
Reproducibility of Results
Rotator Cuff physiopathology
Shoulder Impingement Syndrome physiopathology
Shoulder Joint diagnostic imaging
Acromion diagnostic imaging
Arm diagnostic imaging
Fluoroscopy methods
Humerus diagnostic imaging
Imaging, Three-Dimensional
Rotator Cuff diagnostic imaging
Shoulder Impingement Syndrome diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1532-6500
- Volume :
- 21
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Journal of shoulder and elbow surgery
- Publication Type :
- Academic Journal
- Accession number :
- 22361718
- Full Text :
- https://doi.org/10.1016/j.jse.2011.11.023