Adjuvant intensity-modulated proton therapy in malignant pleural mesothelioma. A comparison with intensity-modulated radiotherapy and a spot size variation assessment.

Authors :
Lorentini S
Amichetti M
Spiazzi L
Tonoli S
Magrini SM
Fellin F
Schwarz M
Source :
Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] [Strahlenther Onkol] 2012 Mar; Vol. 188 (3), pp. 216-25. Date of Electronic Publication: 2012 Feb 10.
Publication Year :
2012

Abstract

Purpose: Intensity-modulated radiation therapy (IMRT) is the state-of-the-art treatment for patients with malignant pleural mesothelioma (MPM). The goal of this work was to assess whether intensity-modulated proton therapy (IMPT) could further improve the dosimetric results allowed by IMRT.<br />Patients and Methods: We re-planned 7 MPM cases using both photons and protons, by carrying out IMRT and IMPT plans. For both techniques, conventional dose comparisons and normal tissue complication probability (NTCP) analysis were performed. In 3 cases, additional IMPT plans were generated with different beam dimensions.<br />Results: IMPT allowed a slight improvement in target coverage and clear advantages in dose conformity (p < 0.001) and dose homogeneity (p = 0.01). Better organ at risk (OAR) sparing was obtained with IMPT, in particular for the liver (D(mean) reduction of 9.5 Gy, p = 0.001) and ipsilateral kidney (V(20) reduction of 58%, p = 0.001), together with a very large reduction of mean dose for the contralateral lung (0.2 Gy vs 6.1 Gy, p = 0.0001). NTCP values for the liver showed a systematic superiority of IMPT with respect to IMRT for both the esophagus (average NTCP 14% vs. 30.5%) and the ipsilateral kidney (p = 0.001). Concerning plans obtained with different spot dimensions, a slight loss of target coverage was observed along with sigma increase, while maintaining OAR irradiation always under planning constraints.<br />Conclusion: Results suggest that IMPT allows better OAR sparing with respect to IMRT, mainly for the liver, ipsilateral kidney, and contralateral lung. The use of a spot dimension larger than 3 × 3 mm (up to 9 × 9 mm) does not compromise dosimetric results and allows a shorter delivery time.

Details

Language :
English
ISSN :
1439-099X
Volume :
188
Issue :
3
Database :
MEDLINE
Journal :
Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]
Publication Type :
Academic Journal
Accession number :
22318326
Full Text :
https://doi.org/10.1007/s00066-011-0038-3