Back to Search
Start Over
Standardized LC-MS/MS based steroid hormone profile-analysis.
- Source :
-
The Journal of steroid biochemistry and molecular biology [J Steroid Biochem Mol Biol] 2012 Apr; Vol. 129 (3-5), pp. 129-38. Date of Electronic Publication: 2011 Dec 27. - Publication Year :
- 2012
-
Abstract
- In order to overcome many limitations of immunoassays, high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has the potential to find its place in the clinical laboratory medicine for quantification of steroid hormones. A prerequisite for the application of a new analytical procedure in clinical diagnostics is standardization to minimize analytical intra- and interlaboratory variability and inaccuracy. We evaluate a newly standardized HPLC-MS/MS assay in kit-format, developed for routine determination of 16 steroid hormones in human serum samples. Fifteen metabolites can be measured quantitatively, which include aldosterone, androstenedione, androsterone, corticosterone, cortisol, cortisone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), 17β-estradiol (E2), estrone (E1), etiocholanolone, 17α-hydroxyprogesterone (17OHP), progesterone, and testosterone. 11-Deoxycorticosterone is the only compound rated as semi-quantitative in this kit. The sample preparation is performed by solid phase extraction (SPE) on a 96-well plate. The standardized assay has been validated for human serum in terms of lower and upper limit of quantification (LLOQ 0.01-32 ng/mL, ULOQ 5-8000 ng/mL), linear correlation coefficient of calibration (R(2)>0.9966), intra- and inter-day precision (intra-day 1.1-8.8%, inter-day 5.2-14.8% and 8.2-18.6% for 11-deoxycorticosterone), accuracy (intra-day 88.3-115.5% and 109.3-128.2% for 11-deoxycorticosterone, inter-day 91.4-117.2% and 102.3-137.1% for 11-deoxycorticosterone), analytical total error (3.6-17.8%), proficiency test accuracy (85.4-113.4%), recovery (68-99%), and metabolite stability (freeze/thaw stability 95.5-108.1%, short term stability 86.9-107.2%). Inter-assay comparison with a routine reference HPLC-MS/MS assay and seven immunoassays demonstrates the outstanding high performance of this HPLC-MS/MS based kit by improvements in accuracy for progesterone, androstenedione, and 17OHP. Finally, results of two metyrapone tests demonstrate the potential of the standardized HPLC-MS/MS assay for the analysis of a comprehensive steroid hormone profile in clinical diagnostics.<br /> (Copyright © 2011 Elsevier Ltd. All rights reserved.)
- Subjects :
- Antimetabolites pharmacology
Child
Chromatography, High Pressure Liquid standards
Female
Humans
Limit of Detection
Male
Metyrapone pharmacology
Reproducibility of Results
Solid Phase Extraction methods
Solid Phase Extraction standards
Tandem Mass Spectrometry standards
Chromatography, High Pressure Liquid methods
Hormones blood
Steroids blood
Tandem Mass Spectrometry methods
Subjects
Details
- Language :
- English
- ISSN :
- 1879-1220
- Volume :
- 129
- Issue :
- 3-5
- Database :
- MEDLINE
- Journal :
- The Journal of steroid biochemistry and molecular biology
- Publication Type :
- Academic Journal
- Accession number :
- 22210511
- Full Text :
- https://doi.org/10.1016/j.jsbmb.2011.12.001