Acute ST changes during anesthesia induction 10 months after Norwood procedure.

Authors :
Hill JA
Qureshi AM
Latson LA
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2012 Feb 15; Vol. 79 (3), pp. 422-6. Date of Electronic Publication: 2011 Dec 08.
Publication Year :
2012

Abstract

After the Norwood procedure for palliation of hypoplastic left heart syndrome, there is still significant interstage and late mortality with often unclear etiology. An important, but possibly under-recognized complication of the Norwood operation is the potential for coronary insufficiency from pre-coronary stenosis due to kinking or scarring at the anastomosis between the native and neo-aorta. We report a case of a clinically thriving 10-month old infant status post bidirectional Glenn who had acute ischemic changes on electrocardiogram (ECG) during induction of anesthesia for elective bilateral herniorrhaphy. A discrete narrowing in the native aorta to neo-aorta anastomosis was identified. A stent was placed emergently to restore adequate coronary blood flow after failure of simple angioplasty to adequately improve the stenosis.<br /> (Copyright © 2011 Wiley Periodicals, Inc.)