Back to Search Start Over

A new complication of coronary arteriography.

Authors :
Raphael MJ
Donaldson RM
Source :
Catheterization and cardiovascular diagnosis [Cathet Cardiovasc Diagn] 1990 Sep; Vol. 21 (1), pp. 55-7.
Publication Year :
1990

Abstract

The introduction of a sharply angulated catheter through an arterial sheath for percutaneous coronary arteriography was associated in 7 cases with dissection of the iliac arteries; this extended to the lumbar aorta at the level of the coeliac axis. The catheter tip should be introduced gently and preferably straightened out with a good length of guide wire to avoid this complication.

Details

Language :
English
ISSN :
0098-6569
Volume :
21
Issue :
1
Database :
MEDLINE
Journal :
Catheterization and cardiovascular diagnosis
Publication Type :
Academic Journal
Accession number :
2208269
Full Text :
https://doi.org/10.1002/ccd.1810210114