Back to Search Start Over

Monitoring the variations of the oxygen transfer rate in a full scale membrane bioreactor using daily mass balances.

Authors :
Racault Y
Stricker AE
Husson A
Gillot S
Source :
Water science and technology : a journal of the International Association on Water Pollution Research [Water Sci Technol] 2011; Vol. 63 (11), pp. 2651-7.
Publication Year :
2011

Abstract

Oxygen transfer in biological wastewater treatment processes with high sludge concentration, such as membrane bioreactor (MBR), is an important issue. The variation of alpha-factor versus mixed liquor suspended solids (MLSS) concentration was investigated in a full scale MBR plant under process conditions, using mass balances. Exhaustive data from the Supervisory Control And Data Acquisition (SCADA) and from additional online sensors (COD, DO, MLSS) were used to calculate the daily oxygen consumption (OC) using a non-steady state mass balance for COD and total N on a 24-h basis. To close the oxygen balance, OC has to match the total oxygen transfer rate (OTRtot) of the system, which is provided by fine bubble (FB) diffusers in the aeration tank and coarse bubbles (CB) in separate membrane tanks. First assessing OTR(CB) then closing the balance OC = OTRtot allowed to calculate OTR(FB) and to fit an exponential relationship between OTR(FB) and MLSS. A comparison of the alpha-factor obtained by this balance method and by direct measurements with the off-gas method on the same plant is presented and discussed.

Details

Language :
English
ISSN :
0273-1223
Volume :
63
Issue :
11
Database :
MEDLINE
Journal :
Water science and technology : a journal of the International Association on Water Pollution Research
Publication Type :
Academic Journal
Accession number :
22049761
Full Text :
https://doi.org/10.2166/wst.2011.146