On the estimation of T-wave alternans using the spectral fast fourier transform method.

Authors :
Armoundas AA
Mela T
Merchant FM
Source :
Heart rhythm [Heart Rhythm] 2012 Mar; Vol. 9 (3), pp. 449-56. Date of Electronic Publication: 2011 Oct 12.
Publication Year :
2012

Abstract

Background: T-wave alternans (TWA) has been associated with increased vulnerability to ventricular tachyarrhythmias and sudden cardiac death. However, both random (white) noise and (patho)physiologic processes (ie, premature ventricular contractions and heart and respiration rates) may hamper TWA estimation and therefore lessen its clinical utility for risk stratification.<br />Objective: To investigate the effect of random noise and certain (patho)physiologic processes on the estimation of TWA by using the fast Fourier transform method and to develop methods to overcome these potential sources of error.<br />Methods: We used a combination of human electrocardiogram data and computer simulations to assess the effects of a premature ventricular contraction and random and colored noise on the accuracy of TWA estimation.<br />Results: We quantitatively demonstrate that replacing a "bad" beat with an odd/even median beat is a more accurate approach than replacing it with the overall average or the overall median beat. We also show that phase resetting may have a significant effect on alternans estimation and that estimation of alternans by using frequencies >0.4922 cycles/beat in a 128-point fast Fourier transform provides the most accurate approach for estimating the alternans when phase resetting is likely to occur. In addition, our data demonstrate that the number of indeterminate TWA tests due to high levels of noise can be reduced when the alternans voltage exceeds a new higher threshold. Furthermore, the amplitude of random noise has a significant effect on alternans estimation and the alternans voltage threshold should be adjusted for noise levels >1.8 μV. Finally, we quantitatively demonstrate that colored noise may lead to a false-positive or a false-negative result. We propose methods to estimate the effect of these (patho)physiologic processes on the alternans estimation in order to determine whether a TWA test is likely to be a true positive or a true negative.<br />Conclusion: This study introduces novel methods to overcome potential sources of error in the estimation of TWA. These methods may improve the utility of TWA either for ambulatory monitoring or for clinical risk stratification for ventricular arrhythmias and sudden cardiac death.<br /> (Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1556-3871
Volume :
9
Issue :
3
Database :
MEDLINE
Journal :
Heart rhythm
Publication Type :
Academic Journal
Accession number :
22001706
Full Text :
https://doi.org/10.1016/j.hrthm.2011.10.013