Cardiovascular magnetic resonance myocardial feature tracking detects quantitative wall motion during dobutamine stress.
- Source :
-
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance [J Cardiovasc Magn Reson] 2011 Oct 12; Vol. 13, pp. 58. Date of Electronic Publication: 2011 Oct 12. - Publication Year :
- 2011
-
Abstract
- Background: Dobutamine stress cardiovascular magnetic resonance (DS-CMR) is an established tool to assess hibernating myocardium and ischemia. Analysis is typically based on visual assessment with considerable operator dependency. CMR myocardial feature tracking (CMR-FT) is a recently introduced technique for tissue voxel motion tracking on standard steady-state free precession (SSFP) images to derive circumferential and radial myocardial mechanics.We sought to determine the feasibility and reproducibility of CMR-FT for quantitative wall motion assessment during intermediate dose DS-CMR.<br />Methods: 10 healthy subjects were studied at 1.5 Tesla. Myocardial strain parameters were derived from SSFP cine images using dedicated CMR-FT software (Diogenes MRI prototype; Tomtec; Germany). Right ventricular (RV) and left ventricular (LV) longitudinal strain (EllRV and EllLV) and LV long-axis radial strain (ErrLAX) were derived from a 4-chamber view at rest. LV short-axis circumferential strain (EccSAX) and ErrSAX; LV ejection fraction (EF) and volumes were analyzed at rest and during dobutamine stress (10 and 20 μg · kg⁻¹· min⁻¹).<br />Results: In all volunteers strain parameters could be derived from the SSFP images at rest and stress. EccSAX values showed significantly increased contraction with DSMR (rest: -24.1 ± 6.7; 10 μg: -32.7 ± 11.4; 20 μg: -39.2 ± 15.2; p < 0.05). ErrSAX increased significantly with dobutamine (rest: 19.6 ± 14.6; 10 μg: 31.8 ± 20.9; 20 μg: 42.4 ± 25.5; p < 0.05). In parallel with these changes; EF increased significantly with dobutamine (rest: 56.9 ± 4.4%; 10 μg: 70.7 ± 8.1; 20 μg: 76.8 ± 4.6; p < 0.05). Observer variability was best for LV circumferential strain (EccSAX ) and worst for RV longitudinal strain (EllRV) as determined by 95% confidence intervals of the difference.<br />Conclusions: CMR-FT reliably detects quantitative wall motion and strain derived from SSFP cine imaging that corresponds to inotropic stimulation. The current implementation may need improvement to reduce observer-induced variance. Within a given CMR lab; this novel technique holds promise of easy and fast quantification of wall mechanics and strain.
- Subjects :
- Adult
Feasibility Studies
Female
Humans
Image Interpretation, Computer-Assisted
Male
Middle Aged
Observer Variation
Predictive Value of Tests
Reference Values
Reproducibility of Results
Stroke Volume
Young Adult
Cardiotonic Agents
Dobutamine
Magnetic Resonance Imaging, Cine
Myocardial Contraction
Ventricular Function, Left
Subjects
Details
- Language :
- English
- ISSN :
- 1532-429X
- Volume :
- 13
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
- Publication Type :
- Academic Journal
- Accession number :
- 21992220
- Full Text :
- https://doi.org/10.1186/1532-429X-13-58