Back to Search Start Over

Invited article: millimeter-wave bolometer array receiver for the Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument.

Authors :
Schwan D
Ade PA
Basu K
Bender AN
Bertoldi F
Cho HM
Chon G
Clarke J
Dobbs M
Ferrusca D
Güsten R
Halverson NW
Holzapfel WL
Horellou C
Johansson D
Johnson BR
Kennedy J
Kermish Z
Kneissl R
Lanting T
Lee AT
Lueker M
Mehl J
Menten KM
Muders D
Pacaud F
Plagge T
Reichardt CL
Richards PL
Schaaf R
Schilke P
Sommer MW
Spieler H
Tucker C
Weiss A
Westbrook B
Zahn O
Source :
The Review of scientific instruments [Rev Sci Instrum] 2011 Sep; Vol. 82 (9), pp. 091301.
Publication Year :
2011

Abstract

The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1' angular resolution and a 22' field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 μK(CMB)√s (NEy of 3.5 × 10(-4) √s). We have also demonstrated upgraded detectors with improved sensitivity of 530 μK(CMB)√s (NEy of 2.2 × 10(-4) √s). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope.<br /> (© 2011 American Institute of Physics)

Details

Language :
English
ISSN :
1089-7623
Volume :
82
Issue :
9
Database :
MEDLINE
Journal :
The Review of scientific instruments
Publication Type :
Academic Journal
Accession number :
21974566
Full Text :
https://doi.org/10.1063/1.3637460