Back to Search
Start Over
Prospective, randomized, fellow eye comparison of WaveLight Allegretto Wave Eye-Q versus VISX CustomVueTM STAR S4 IRTM in photorefractive keratectomy: analysis of visual outcomes and higher-order aberrations.
- Source :
-
Clinical ophthalmology (Auckland, N.Z.) [Clin Ophthalmol] 2011; Vol. 5, pp. 1185-93. Date of Electronic Publication: 2011 Aug 22. - Publication Year :
- 2011
-
Abstract
- Background: The purpose of this study was to compare differences in visual outcomes, higher-order aberrations, contrast sensitivity, and dry eye in patients undergoing photorefractive keratectomy using wavefront-guided VISX CustomVue™ and wavefront-optimized WaveLight(®) Allegretto platforms.<br />Methods: In this randomized, prospective, single-masked, fellow-eye study, photorefractive keratectomy was performed on 46 eyes from 23 patients, with one eye randomized to WaveLight Allegretto, and the fellow eye receiving VISX CustomVue. Three-month postoperative outcome measures included uncorrected distance visual acuity, corrected distance visual acuity, refractive error, root mean square of total and grouped higher-order aberrations, contrast sensitivity, and Schirmer's testing.<br />Results: Mean values for uncorrected distance visual acuity (logMAR) were -0.03 ± 0.07 and -0.06 ± 0.09 in the wavefront-optimized and wavefront-guided groups, respectively (P = 0.121). Uncorrected distance visual acuity of 20/20 or better was achieved in 91% of eyes receiving wavefront-guided photorefractive keratectomy, and 87% of eyes receiving wavefront-optimized photorefractive keratectomy, whereas uncorrected distance visual acuity of 20/15 was achieved in 35% of the wavefront-optimized group and 64% of the wavefront-guided group (P ≥ 0.296). While root mean square of total higher-order aberration, coma, and trefoil tended to increase in the wavefront-optimized group (P = 0.091, P = 0.115, P = 0.459, respectively), only spherical aberration increased significantly (P = 0.014). Similar increases were found in wavefront- guided root mean square of total higher-order aberration (P = 0.113), coma (P = 0.403), trefoil (P = 0.603), and spherical aberration (P = 0.014). There was no significant difference in spherical aberration change when comparing the two platforms. The wavefront-guided group showed an increase in contrast sensitivity at 12 cycles per degree (P = 0.013).<br />Conclusion: Both VISX CustomVue and WaveLight Allegretto platforms performed equally in terms of visual acuity, safety, and predictability in photorefractive keratectomy. The wavefront-guided group showed slightly improved contrast sensitivity. Both lasers induced a comparable degree of statistically significant spherical aberration, and tended to increase other higher-order aberration measures as well.
Details
- Language :
- English
- ISSN :
- 1177-5483
- Volume :
- 5
- Database :
- MEDLINE
- Journal :
- Clinical ophthalmology (Auckland, N.Z.)
- Publication Type :
- Academic Journal
- Accession number :
- 21966184
- Full Text :
- https://doi.org/10.2147/OPTH.S24319