Back to Search Start Over

Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body.

Authors :
Tward DJ
Ceritoglu C
Kolasny A
Sturgeon GM
Segars WP
Miller MI
Ratnanather JT
Source :
International journal of biomedical imaging [Int J Biomed Imaging] 2011; Vol. 2011, pp. 481064. Date of Electronic Publication: 2011 Sep 25.
Publication Year :
2011

Abstract

This paper describes an automated procedure for creating detailed patient-specific pediatric dosimetry phantoms from a small set of segmented organs in a child's CT scan. The algorithm involves full body mappings from adult template to pediatric images using multichannel large deformation diffeomorphic metric mapping (MC-LDDMM). The parallel implementation and performance of MC-LDDMM for this application is studied here for a sample of 4 pediatric patients, and from 1 to 24 processors. 93.84% of computation time is parallelized, and the efficiency of parallelization remains high until more than 8 processors are used. The performance of the algorithm was validated on a set of 24 male and 18 female pediatric patients. It was found to be accurate typically to within 1-2 voxels (2-4 mm) and robust across this large and variable data set.

Details

Language :
English
ISSN :
1687-4196
Volume :
2011
Database :
MEDLINE
Journal :
International journal of biomedical imaging
Publication Type :
Academic Journal
Accession number :
21960989
Full Text :
https://doi.org/10.1155/2011/481064