Abstract
- Background: To investigate the utility of three-dimensional guide-point modeling (GPM) to reduce the time required for CMR evaluation of global cardiac function in mice, by reducing the number of image slices required for accurate quantification of left-ventricular (LV) mass and volumes.<br />Methods: Five female C57Bl/6 mice 8 weeks post myocardial infarction induced by permanent occlusion of the left coronary artery, and six male control (un-operated) C57Bl/6 mice, were subject to CMR examination under isoflurane anaesthesia. Contiguous short axis (SAX) slices (1 mm thick 7-9 slices) were obtained together with two long axis (LAX) slices in two chamber and four chamber orientations. Using a mathematical model of the heart to interpolate information between the available slices, GPM LV mass and volumes were determined using full slice (all SAX and two LAX), six slice (four SAX and two LAX) and four slice (two SAX and two LAX) analysis protocols. All results were compared with standard manual volumetric analysis using all SAX slices.<br />Results: Infarct size was 39.1±5.1% of LV myocardium. No significant differences were found in left ventricular mass and volumes between the standard and GPM full and six slice protocols in infarcted mice (113±10, 116±11, and 117±11 mg respectively for mass), or between the standard and GPM full, six and four slice protocols in control mice, (105±14, 106±10, 104±12, and 105±7 mg respectively for mass). Significant differences were found in LV mass (135±18 mg) and EF using the GPM four slice protocol in infarcted mice (p<0.05).<br />Conclusion: GPM enables accurate analysis of LV function in mice with relatively large infarcts using a reduced six slice acquisition protocol, and in mice with normal/symmetrical left-ventricular topology using a four slice protocol.
- Subjects :
- Animals
Disease Models, Animal
Female
Male
Mice
Mice, Inbred C57BL
Models, Cardiovascular
Myocardial Infarction complications
Myocardial Infarction physiopathology
Predictive Value of Tests
Time Factors
Ventricular Dysfunction, Left etiology
Ventricular Dysfunction, Left physiopathology
Image Processing, Computer-Assisted
Imaging, Three-Dimensional
Magnetic Resonance Imaging
Myocardial Infarction diagnosis
Myocardium pathology
Ventricular Dysfunction, Left diagnosis
Ventricular Function, Left
Subjects
Details
- Language :
- English
- ISSN :
- 1532-429X
- Volume :
- 13
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
- Publication Type :
- Academic Journal
- Accession number :
- 21917165
- Full Text :
- https://doi.org/10.1186/1532-429X-13-49