Back to Search Start Over

Development and preliminary validation of a magnetic resonance imaging joint space narrowing score for use in rheumatoid arthritis: potential adjunct to the OMERACT RA MRI scoring system.

Authors :
Ostergaard M
Bøyesen P
Eshed I
Gandjbakhch F
Lillegraven S
Bird P
Foltz V
Boonen A
Lassere M
Hermann KG
Anandarajah A
Døhn UM
Freeston J
Peterfy CG
Genant HK
Haavardsholm EA
McQueen FM
Conaghan PG
Source :
The Journal of rheumatology [J Rheumatol] 2011 Sep; Vol. 38 (9), pp. 2045-50.
Publication Year :
2011

Abstract

Objective: To develop and validate a magnetic resonance imaging (MRI) method of assessment of joint space narrowing (JSN) in rheumatoid arthritis (RA).<br />Methods: Phase A: JSN was scored 0-4 on MR images of 5 RA patients and 3 controls at 15 wrist sites and 2nd-5th metacarpophalangeal (MCP) joints by 8 readers (7 once, one twice), using a preliminary scoring system. Phase B: Image review, discussion, and consensus on JSN definition, and revised scoring system. Phase C: MR images of 15 RA patients and 4 controls were scored using revised system by 5 readers (4 once, one twice), and results compared with radiographs [Sharp-van der Heijde (SvdH) method].<br />Results: Phase A: Intraobserver agreement: intraclass correlation coefficient (ICC) = 0.99; smallest detectable difference (SDD, for mean of readings) = 2.8 JSN units (4.9% of observed maximal score). Interobserver agreement: ICC = 0.93; SDD = 6.4 JSN units (9.9%). Phase B: Agreement was reached on JSN definition (reduced joint space width compared to normal, as assessed in a slice perpendicular to the joint surface), and revised scoring system (0-4 at 17 wrist sites and 2nd-5th MCP; 0: none; 1: 1-33%; 2: 34-66%; 3: 67-99%; 4: ankylosis). Phase C: Intraobserver agreement: ICC = 0.90; SDD = 6.8 JSN units (11.0%). Interobserver agreement: ICC = 0.92 and SDD = 6.2 JSN units (8.7%). The correlation (ICC) with the SvdH radiographic JSN score of the wrist/hand was 0.77. Simplified approaches evaluating fewer joint spaces demonstrated similar reliability and correlation with radiographic scores.<br />Conclusion: An MRI scoring system of JSN in RA wrist and MCP joints was developed and showed construct validity and good intra- and interreader agreements. The system may, after further validation in longitudinal data sets, be useful as an outcome measure in RA.

Details

Language :
English
ISSN :
0315-162X
Volume :
38
Issue :
9
Database :
MEDLINE
Journal :
The Journal of rheumatology
Publication Type :
Academic Journal
Accession number :
21885515
Full Text :
https://doi.org/10.3899/jrheum.110422