Back to Search Start Over

Characterization of aqueous silver nitrate solutions for leakage tests.

Authors :
Costa JF
Siqueira WL
Loguercio AD
Reis A
Oliveira Ed
Alves CM
Bauer JR
Grande RH
Source :
Journal of applied oral science : revista FOB [J Appl Oral Sci] 2011 May-Jun; Vol. 19 (3), pp. 254-9.
Publication Year :
2011

Abstract

Objectives: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated.<br />Material and Methods: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled) and three brands of silver nitrate salt (Merck, Synth or Cennabras) at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h) and concentrations (1, 5, 25, 50%) of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO₃ solution and the primary teeth in 5% or 50% AgNO₃ solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%).<br />Results: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9). Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm). In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000).<br />Conclusions: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO₃ solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were capable of indicating loss of marginal seal in the composite restorations; the 3-step conventional adhesive system had better performance regarding microleakage in enamel on primary and permanent teeth.

Details

Language :
English
ISSN :
1678-7765
Volume :
19
Issue :
3
Database :
MEDLINE
Journal :
Journal of applied oral science : revista FOB
Publication Type :
Academic Journal
Accession number :
21625743
Full Text :
https://doi.org/10.1590/s1678-77572011000300014