Cone-beam CT-based delineation of stereotactic lung targets: the influence of image modality and target size on interobserver variability.
- Source :
-
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2012 Feb 01; Vol. 82 (2), pp. e265-72. Date of Electronic Publication: 2011 May 27. - Publication Year :
- 2012
-
Abstract
- Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated.<br />Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient.<br />Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI(genA) = 0.62 ± 0.06 vs. CI(genB) = 0.70 ± 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability.<br />Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.<br /> (Copyright © 2012 Elsevier Inc. All rights reserved.)
- Subjects :
- Analysis of Variance
Carcinoma, Non-Small-Cell Lung pathology
Carcinoma, Non-Small-Cell Lung surgery
Humans
Lung diagnostic imaging
Lung Neoplasms pathology
Lung Neoplasms secondary
Lung Neoplasms surgery
Observer Variation
Radiation Oncology
Radiotherapy Planning, Computer-Assisted methods
Reproducibility of Results
Statistics, Nonparametric
Tomography, X-Ray Computed methods
Carcinoma, Non-Small-Cell Lung diagnostic imaging
Cone-Beam Computed Tomography
Lung Neoplasms diagnostic imaging
Radiosurgery
Tumor Burden
Subjects
Details
- Language :
- English
- ISSN :
- 1879-355X
- Volume :
- 82
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- International journal of radiation oncology, biology, physics
- Publication Type :
- Academic Journal
- Accession number :
- 21620581
- Full Text :
- https://doi.org/10.1016/j.ijrobp.2011.03.042