Back to Search Start Over

Descending aortic diameter of 5.5 cm or greater is not an accurate predictor of acute type B aortic dissection.

Authors :
Trimarchi S
Jonker FH
Hutchison S
Isselbacher EM
Pape LA
Patel HJ
Froehlich JB
Muhs BE
Rampoldi V
Grassi V
Evangelista A
Meinhardt G
Beckman J
Myrmel T
Pyeritz RE
Hirsch AT
Sundt TM 3rd
Nienaber CA
Eagle KA
Source :
The Journal of thoracic and cardiovascular surgery [J Thorac Cardiovasc Surg] 2011 Sep; Vol. 142 (3), pp. e101-7. Date of Electronic Publication: 2011 May 17.
Publication Year :
2011

Abstract

Objective: The risk of acute type B aortic dissection is thought to increase with descending thoracic aortic diameter. Currently, elective repair of the descending thoracic aorta is indicated for an aortic diameter of 5.5 cm or greater. We sought to investigate the relationship between aortic diameter and acute type B aortic dissection, and the utility of aortic diameter as a predictor of acute type B aortic dissection.<br />Methods: We examined the descending aortic diameter at presentation of 613 patients with acute type B aortic dissection who were enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2009, and analyzed the subset of patients with acute type B aortic dissection with an aortic diameter less than 5.5 cm.<br />Results: The median aortic diameter at the level of acute type B aortic dissection was 4.1 cm (range 2.1-13.0 cm). Only 18.4% of patients with acute type B aortic dissection in the International Registry of Acute Aortic Dissection had an aortic diameter of 5.5 cm or greater. Patients with Marfan syndrome represented 4.3% and had a slightly larger aortic diameter than patients without Marfan syndrome (4.68 vs 4.32 cm, P = .121). Complicated acute type B aortic dissection was more common among patients with an aortic diameter of 5.5 cm or greater (52.2% vs 35.6%, P < .001), and the in-hospital mortality for patients with an aortic diameter less than 5.5 cm and 5.5 cm or greater was 6.6% and 23.0% (P < .001), respectively.<br />Conclusions: The majority of patients with acute type B aortic dissection present with a descending aortic diameter less than 5.5 cm before dissection and are not within the guidelines for elective descending thoracic aortic repair. Aortic diameter measurements do not seem to be a useful parameter to prevent aortic dissection, and other methods are needed to identify patients at risk for acute type B aortic dissection.<br /> (Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1097-685X
Volume :
142
Issue :
3
Database :
MEDLINE
Journal :
The Journal of thoracic and cardiovascular surgery
Publication Type :
Academic Journal
Accession number :
21592525
Full Text :
https://doi.org/10.1016/j.jtcvs.2010.12.032