Back to Search Start Over

Retrieval of detached fragment of central venous pressure catheter (CVP) lodged in the right ventricle and pulmonary artery: a case report.

Authors :
Sakijan AS
Zambahari R
Annuar Z
Yahya O
Ali J
Source :
The Medical journal of Malaysia [Med J Malaysia] 1990 Dec; Vol. 45 (4), pp. 340-3.
Publication Year :
1990

Abstract

A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detached catheter fragment by percutaneous means obviates the need for thoracotomy.

Details

Language :
English
ISSN :
0300-5283
Volume :
45
Issue :
4
Database :
MEDLINE
Journal :
The Medical journal of Malaysia
Publication Type :
Academic Journal
Accession number :
2152057