Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.

Authors :
Achenbach S
Goroll T
Seltmann M
Pflederer T
Anders K
Ropers D
Daniel WG
Uder M
Lell M
Marwan M
Source :
JACC. Cardiovascular imaging [JACC Cardiovasc Imaging] 2011 Apr; Vol. 4 (4), pp. 328-37.
Publication Year :
2011

Abstract

Objectives: We sought to evaluate the diagnostic accuracy of a new prospectively electrocardiogram (ECG)-triggered high-pitch scan mode for coronary computed tomography angiography (CTA), which allows an effective dose of less than 1 mSv.<br />Background: Coronary CTA provides increasingly reliable image quality, but the associated radiation exposure can be high.<br />Methods: Seventy-five patients with suspected coronary artery disease and in sinus rhythm were screened for participation. After exclusion of 25 patients for body weight >100 kg or failure to lower heart rate to ≤ 60 beats/min, 50 patients were studied by prospectively ECG-triggered high-pitch spiral computed tomography (CT). Coronary CTA was performed using a dual-source CT system with 2 × 128 × 0.6-mm collimation, 0.28-s rotation time, a pitch of 3.4, 100-kVp tube voltage, and current of 320 mA. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within 1 cardiac cycle. Diagnostic accuracy for detection of coronary artery stenoses ≥ 50% diameter stenosis was determined by comparison to invasive coronary angiography. Per-patient diagnostic performance was the primary form of analysis.<br />Results: In all 50 patients (34 males, 59 ± 12 years of age), imaging was successful. For the detection of 16 patients with at least 1 coronary artery stenosis, CT demonstrated a sensitivity of 100% (95% confidence interval [CI]: 79% to 100%) and specificity of 82% (95% CI: 65% to 93%). The positive predictive value was 72% (95% CI: 49% to 89%) and the negative predictive value was 100% (95% CI: 87% to 100%). Sensitivity was 100% (95% CI: 88% to 100%) and specificity was 94% (95% CI: 89% to 97%) on a per-vessel basis. Per-segment sensitivity was 92% (95% CI: 80% to 97%), and specificity was 98% (95% CI: 96% to 98%). Mean dose-length product for coronary CTA was 54 ± 6 mGy · cm, the effective dose was 0.76 ± 0.08 mSv (0.64 to 0.95 mSv).<br />Conclusions: In nonobese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides high diagnostic accuracy for the detection of coronary artery stenoses.<br /> (Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1876-7591
Volume :
4
Issue :
4
Database :
MEDLINE
Journal :
JACC. Cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
21492807
Full Text :
https://doi.org/10.1016/j.jcmg.2011.01.012