Flow changes after endovascular treatment of a wide-neck anterior communicating artery aneurysm by using X-configured kissing stents (cross-kissing stents) technique.

Authors :
Zeleňák K
Zeleňáková J
DeRiggo J
Kurča E
Boudný J
Poláček H
Source :
Cardiovascular and interventional radiology [Cardiovasc Intervent Radiol] 2011 Dec; Vol. 34 (6), pp. 1308-11. Date of Electronic Publication: 2011 Mar 31.
Publication Year :
2011

Abstract

Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.