Back to Search Start Over

MR elastography monitoring of tissue-engineered constructs.

Authors :
Othman SF
Curtis ET
Plautz SA
Pannier AK
Butler SD
Xu H
Source :
NMR in biomedicine [NMR Biomed] 2012 Mar; Vol. 25 (3), pp. 452-63. Date of Electronic Publication: 2011 Mar 08.
Publication Year :
2012

Abstract

The objective of tissue engineering (TE) is to create functional replacements for various tissues; the mechanical properties of these engineered constructs are critical to their function. Several techniques have been developed for the measurement of the mechanical properties of tissues and organs; however, current methods are destructive. The field of TE will benefit immensely if biomechanical models developed by these techniques could be combined with existing imaging modalities to enable noninvasive, dynamic assessment of mechanical properties during tissue growth. Specifically, MR elastography (MRE), which is based on the synchronization of a mechanical actuator with a phase contrast imaging pulse sequence, has the capacity to measure tissue strain generated by sonic cyclic displacement. The captured displacement is presented in shear wave images from which the complex shear moduli can be extracted or simplified by a direct measure, termed the shear stiffness. MRE has been extended to the microscopic scale, combining clinical MRE with high-field magnets, stronger magnetic field gradients and smaller, more sensitive, radiofrequency coils, enabling the interrogation of smaller samples, such as tissue-engineered constructs. The following topics are presented in this article: (i) current mechanical measurement techniques and their limitations in TE; (ii) a description of the MRE system, MRE theory and how it can be applied for the measurement of mechanical properties of tissue-engineered constructs; (iii) a summary of in vitro MRE work for the monitoring of osteogenic and adipogenic tissues originating from human adult mesenchymal stem cells (MSCs); (iv) preliminary in vivo studies of MRE of tissues originating from mouse MSCs implanted subcutaneously in immunodeficient mice with an emphasis on in vivo MRE challenges; (v) future directions to resolve current issues with in vivo MRE in the context of how to improve the future role of MRE in TE.<br /> (Copyright © 2011 John Wiley & Sons, Ltd.)

Details

Language :
English
ISSN :
1099-1492
Volume :
25
Issue :
3
Database :
MEDLINE
Journal :
NMR in biomedicine
Publication Type :
Academic Journal
Accession number :
21387443
Full Text :
https://doi.org/10.1002/nbm.1663