Back to Search Start Over

Three-dimensional MDCT for preoperative local staging of gastric cancer using gas and water distention methods: a retrospective cohort study.

Authors :
Park HS
Lee JM
Kim SH
Lee JY
Yang HK
Han JK
Choi BI
Source :
AJR. American journal of roentgenology [AJR Am J Roentgenol] 2010 Dec; Vol. 195 (6), pp. 1316-23.
Publication Year :
2010

Abstract

Objective: The purpose of this article is to compare the T-staging accuracy and lesion detectability of MDCT with gas distention versus water distention according to the surgical and histopathologic findings, for the preoperative evaluation of gastric cancer.<br />Materials and Methods: For a 3-month period, 113 consecutive patients (72 men and 41 women; age range, 23-85 years; mean age, 58 years) with 116 surgically confirmed gastric cancers from a single institution were included in our study. All patients had undergone preoperative MDCT with either effervescent granules taken orally (n = 55) or after having drunk 1,000 mL of tap water (n = 58) to create gastric distention. In addition to transverse images, multiplanar reformation images and 3D surface shaded display images were also obtained with gas distention CT, and multiplanar reformation images were obtained with water distention CT. The CT images were retrospectively reviewed by two abdominal radiologists separately with regard to T staging and lesion detectability. The accuracy values were compared between the two methods using Fisher's exact test.<br />Results: The T-staging accuracy for gastric cancer did not differ significantly between gas distention and water distention CT scans, according to both radiologists (p > 0.05). Furthermore, the staging accuracy values for T1a cancers on gas distention CT scans for radiologists 1 and 2 were also comparable with those of water distention CT scans (91.1% vs 85% for radiologist 1 and 89.3% vs 85% for radiologist 2; p > 0.05). However, the tumor detection rate was significantly higher on gas distention CT scans using 2D and surface shaded display images for both radiologists (94.6% for radiologist 1 and 91.1% for radiologist 2), compared with the rates for water distention CT scans (78.3% and 73.3%) or gas distention CT scans using only 2D images (75.0% and 67.9%) (p < 0.05).<br />Conclusion: MDCT using the gas distention technique showed performance comparable to that of the water distention technique for the T staging of preoperative gastric cancer with better lesion detectability.

Details

Language :
English
ISSN :
1546-3141
Volume :
195
Issue :
6
Database :
MEDLINE
Journal :
AJR. American journal of roentgenology
Publication Type :
Academic Journal
Accession number :
21098189
Full Text :
https://doi.org/10.2214/AJR.10.4320