Back to Search
Start Over
Quantitative comparison of thermal dose models in normal canine brain.
- Source :
-
Medical physics [Med Phys] 2010 Oct; Vol. 37 (10), pp. 5313-21. - Publication Year :
- 2010
-
Abstract
- Purpose: Minimally invasive thermal ablative therapies as alternatives to conventional surgical management of solid tumors and other pathologies is increasing owing to the potential benefits of performing these procedures in an outpatient setting with reduced complications and comorbidity. Magnetic resonance temperature imaging (MRTI) measurement allows existing thermal dose models to use the spatiotemporal temperature history to estimate the thermal damage to tissue. However, the various thermal dose models presented in the literature employ different parameters and thresholds, affecting the reliability of thermal dosimetry. In this study, the authors quantitatively compared three thermal dose models (Arrhenius rate process, CEM43, and threshold temperature) using the dice similarity coefficient (DSC).<br />Methods: The DSC was used to compare the spatial overlap between the region of thermal damage as predicted by the models for in vivo normal canine brain during thermal therapy to the region of thermal damage as revealed by contrast-enhanced T1-weighted images acquired immediately after therapy (< 20 min). The outer edge of the hyperintense rim of the ablation region was used as the surrogate marker for the limits of thermal coagulation. The DSC was also used to investigate the impact of varying the thresholds on each models' ability to predict the zone of thermal necrosis.<br />Results: At previously reported thresholds, the authors found that all three models showed good agreement (defined as DSC > 0.7) with post-treatment imaging. All three models examined across the range of commonly applied thresholds consistently showed highly accurate spatial overlap, low variability, and little dependence on temperature uncertainty. DSC values corresponding to cited thresholds were not significantly different from peak DSC values.<br />Conclusions: Thus, the authors conclude that the all three thermal dose models can be used as a reliable surrogate for postcontrast tissue damage verification imaging in rapid ablation procedures and can also be used to enhance the capability of MRTI to control thermal therapy in real time.
- Subjects :
- Animals
Biophysical Phenomena
Body Temperature
Brain anatomy & histology
Brain Diseases therapy
Dogs
Hyperthermia, Induced statistics & numerical data
Laser Therapy statistics & numerical data
Magnetic Resonance Imaging
Models, Statistical
Thermodynamics
Brain physiology
Hot Temperature therapeutic use
Subjects
Details
- Language :
- English
- ISSN :
- 0094-2405
- Volume :
- 37
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- Medical physics
- Publication Type :
- Academic Journal
- Accession number :
- 21089766
- Full Text :
- https://doi.org/10.1118/1.3490085