Reduction in radiation exposure during coronary angiography.

Authors :
Carpenter ML
Singer PR
Jain A
Dehmer GJ
Source :
Catheterization and cardiovascular diagnosis [Cathet Cardiovasc Diagn] 1990 Nov; Vol. 21 (3), pp. 195-7.
Publication Year :
1990

Abstract

In addition to lead shielding, increased distance between the operator and x-ray source will lower radiation exposure. To utilize this principle, we interposed a 24 in. piece of pressure tubing between the catheter used for coronary angiography and the manifold apparatus. Radiation exposure to the hand of the operator during coronary angiography was compared with and without the extension tubing. When corrected for the differences in exposure time, operator exposure was 5.38 mrem/min without the extension and 4.84 mrem/min with the extension. Although this is a small difference in exposure/min, a substantial reduction in exposure could accumulate over a 1 yr period. Insertion of this extension tube into the catheter system is a simple and safe way to further reduce operator exposure during coronary angiography.

Details

Language :
English
ISSN :
0098-6569
Volume :
21
Issue :
3
Database :
MEDLINE
Journal :
Catheterization and cardiovascular diagnosis
Publication Type :
Academic Journal
Accession number :
2101591
Full Text :
https://doi.org/10.1002/ccd.1810210314