Back to Search Start Over

Effectiveness, suitability, and performance testing of the SKC Deployable Particulate Sampler (DPS) as compared to the currently deployed Airmetrics MiniVol portable air sampler.

Authors :
Patterson SL
Rusiecki JA
Barnes SL
Heller JM
Sutphin JB
Kluchinsky TA Jr
Source :
Journal of environmental health [J Environ Health] 2010 Oct; Vol. 73 (3), pp. 16-22.
Publication Year :
2010

Abstract

Epidemiological studies have linked particulate matter (PM) exposure to morbidity and mortality from cardiovascular and respiratory disease. In order to monitor and assess the potential PM health risk to deployed military personnel, the U.S. Army must field a portable sampler that can accurately sample particles with an aerodynamic diameter less than or equal to a nominal 2.5 mm (PM2.5). In the study described in this article, the SKC Deployable Particulate Sampler (DPS) was compared to the currently deployed Airmetrics MiniVol portable air sampler in the hot, dry environment of Yuma Proving Grounds, Arizona, and the cold, wet environment of Fort Drum, New York. For all measurements taken and averaged, the DPS and the MiniVol did not differ significantly for mean concentration collected; however, the DPS collected 4.0 times more mass than the MiniVol (p < .05). The DPS was shown to be an improvement over the MiniVol when evaluated for measures of effectiveness, suitability, and performance.

Details

Language :
English
ISSN :
0022-0892
Volume :
73
Issue :
3
Database :
MEDLINE
Journal :
Journal of environmental health
Publication Type :
Academic Journal
Accession number :
20960983