Back to Search Start Over

Recurrence of B-cell lymphoma within an implantable cardioverter defibrillator wound scar.

Authors :
Nayar V
Wright P
Pugh PJ
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2011 Mar; Vol. 13 (3), pp. 443-4. Date of Electronic Publication: 2010 Oct 14.
Publication Year :
2011

Abstract

A 79-year-old man presented with relapse of non-Hodgkin's B-cell lymphoma within the scar from his implantable cardioverter defibrillator (ICD) implantation. The ICD was re-sited before he proceeded to chest wall radiotherapy, which resulted in complete remission of the lymphoma. This is the first reported case of lymphoma recurrence within an ICD wound scar.

Details

Language :
English
ISSN :
1532-2092
Volume :
13
Issue :
3
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
20947569
Full Text :
https://doi.org/10.1093/europace/euq367