Back to Search Start Over

Residual seminal vesicle displacement in marker-based image-guided radiotherapy for prostate cancer and the impact on margin design.

Authors :
Smitsmans MH
de Bois J
Sonke JJ
Catton CN
Jaffray DA
Lebesque JV
van Herk M
Source :
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2011 Jun 01; Vol. 80 (2), pp. 590-6. Date of Electronic Publication: 2010 Oct 01.
Publication Year :
2011

Abstract

Purpose: The objectives of this study were to quantify residual interfraction displacement of seminal vesicles (SV) and investigate the efficacy of rotation correction on SV displacement in marker-based prostate image-guided radiotherapy (IGRT). We also determined the effect of marker registration on the measured SV displacement and its impact on margin design.<br />Methods and Materials: SV displacement was determined relative to marker registration by using 296 cone beam computed tomography scans of 13 prostate cancer patients with implanted markers. SV were individually registered in the transverse plane, based on gray-value information. The target registration error (TRE) for the SV due to marker registration inaccuracies was estimated. Correlations between prostate gland rotations and SV displacement and between individual SV displacements were determined.<br />Results: The SV registration success rate was 99%. Displacement amounts of both SVs were comparable. Systematic and random residual SV displacements were 1.6 mm and 2.0 mm in the left-right direction, respectively, and 2.8 mm and 3.1 mm in the anteroposterior (AP) direction, respectively. Rotation correction did not reduce residual SV displacement. Prostate gland rotation around the left-right axis correlated with SV AP displacement (R(2) = 42%); a correlation existed between both SVs for AP displacement (R(2) = 62%); considerable correlation existed between random errors of SV displacement and TRE (R(2) = 34%).<br />Conclusions: Considerable residual SV displacement exists in marker-based IGRT. Rotation correction barely reduced SV displacement, rather, a larger SV displacement was shown relative to the prostate gland that was not captured by the marker position. Marker registration error partly explains SV displacement when correcting for rotations. Correcting for rotations, therefore, is not advisable when SV are part of the target volume. Margin design for SVs should take these uncertainties into account.<br /> (Copyright © 2011 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1879-355X
Volume :
80
Issue :
2
Database :
MEDLINE
Journal :
International journal of radiation oncology, biology, physics
Publication Type :
Academic Journal
Accession number :
20888710
Full Text :
https://doi.org/10.1016/j.ijrobp.2010.06.026