Back to Search Start Over

Determination of aniracetam and its main metabolite, N-anisoyl-GABA, in human plasma by high-performance liquid chromatography.

Authors :
Guenzi A
Zanetti M
Source :
Journal of chromatography [J Chromatogr] 1990 Sep 14; Vol. 530 (2), pp. 397-406.
Publication Year :
1990

Abstract

Two different reversed-phase high-performance liquid chromatographic methods for the determination of aniracetam (I) and its metabolite N-anisoyl-GABA (II) in human plasma are described. The procedure for I involves direct injection of plasma samples spiked with the internal standard on a clean-up column followed by reversed-phase chromatography on a C18 column. The limit of quantification was 5 ng/ml, using a 200-microliters specimen of plasma. The mean inter-assay precision of the method up to 800 ng/ml was 3%. The procedure for II involved liquid-liquid extraction of II and the internal standard from plasma with ethyl acetate, and reversed-phase chromatography on a C18 column. The limit of quantification was 50 ng/ml using a 0.5-ml plasma specimen. The mean inter-assay precision up to 50 micrograms/ml was 6%. The applicability and accuracy of the methods were demonstrated by the analysis of over 1000 plasma samples from two bioavailability studies in healthy volunteers.

Details

Language :
English
Volume :
530
Issue :
2
Database :
MEDLINE
Journal :
Journal of chromatography
Publication Type :
Academic Journal
Accession number :
2079514
Full Text :
https://doi.org/10.1016/s0378-4347(00)82342-7