Back to Search
Start Over
Promoting fusion in minimally invasive lumbar interbody stabilization with low-dose bone morphogenic protein-2--but what is the cost?
- Source :
-
The spine journal : official journal of the North American Spine Society [Spine J] 2011 Jun; Vol. 11 (6), pp. 527-33. Date of Electronic Publication: 2010 Aug 24. - Publication Year :
- 2011
-
Abstract
- Background: Using bone morphogenic protein (BMP) to augment fusion in spine surgery is widespread and lends itself in particular to minimally invasive lumbar fusion, where the surface area for fusion is significantly less than the equivalent open procedure.<br />Purpose: Here we described the use of very low-dose BMP in promoting fusion in minimally invasive lumbar interbody fixation but also highlight some of the potential complications of BMP-2 use and techniques available to reduce or avoid them.<br />Study Design: Prospective observational study of consecutive patients undergoing minimally invasive lumbar interbody fusion with percutaneous pedicle screws.<br />Patient Sample: Thirty patients aged between 22 and 78 years (mean 53 years).<br />Outcome Measures: Thin-slice lumbar computed tomography scanning with multiplanar reconstruction at 6 and 12 months postoperative.<br />Methods: Thirty-six spinal levels were instrumented in total, of which four underwent posterior lumbar interbody fusion and 32 underwent transforaminal lumbar interbody fusion. Bone graft harvested locally was placed in the disc space with low-dose BMP-2 (1.4 mg per level).<br />Results: Thirty-three of 36 spinal levels showed complete fusion at a mean postoperative scan time of 7.1 months. Two levels demonstrated partial fusion at 6 months, which was complete at 12 months. There was one case of nonunion at 12 months, which also demonstrated vertebral body osteolysis. Despite very low-dose BMP-2, two cases of asymptomatic heterotopic ossification were observed, and there were two cases of perineural cyst formation, one of whom required revision of the interbody cage.<br />Conclusions: The use of BMP with autograft in the disc space during minimally invasive lumbar interbody fusion is associated with a high rate of early fusion. Even with very low-dose BMP used in this study, complications related to BMP usage were not avoided completely.<br /> (Copyright © 2011 Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aged
Cysts chemically induced
Cysts epidemiology
Cysts pathology
Female
Humans
Lumbar Vertebrae
Male
Middle Aged
Ossification, Heterotopic chemically induced
Ossification, Heterotopic epidemiology
Ossification, Heterotopic pathology
Osteolysis chemically induced
Osteolysis epidemiology
Osteolysis pathology
Postoperative Complications chemically induced
Postoperative Complications epidemiology
Recombinant Proteins adverse effects
Spinal Fusion adverse effects
Treatment Outcome
Young Adult
Bone Morphogenetic Protein 2 adverse effects
Postoperative Complications pathology
Spinal Fusion methods
Transforming Growth Factor beta adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1878-1632
- Volume :
- 11
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- The spine journal : official journal of the North American Spine Society
- Publication Type :
- Academic Journal
- Accession number :
- 20739225
- Full Text :
- https://doi.org/10.1016/j.spinee.2010.07.005