Back to Search
Start Over
Comparison of Mg-based multilayers for solar He II radiation at 30.4 nm wavelength.
- Source :
-
Applied optics [Appl Opt] 2010 Jul 10; Vol. 49 (20), pp. 3922-5. - Publication Year :
- 2010
-
Abstract
- Mg-based multilayers, including SiC/Mg, Co/Mg, B(4)C/Mg, and Si/Mg, are investigated for solar imaging and a He II calibration lamp at a 30.4 nm wavelength. These multilayers were fabricated by a magnetron sputtering method and characterized by x-ray reflection. The reflectivities of these multilayers were measured by synchrotron radiation. Near-normal-incidence reflectivities of Co/Mg and SiC/Mg multilayer mirrors are as high as 40.3% and 44.6%, respectively, while those of B(4)C/Mg and Si/Mg mirrors are too low for application. The measured results suggest that SiC/Mg, Co/Mg multilayers are promising for a 30.4 nm wavelength.
Details
- Language :
- English
- ISSN :
- 1539-4522
- Volume :
- 49
- Issue :
- 20
- Database :
- MEDLINE
- Journal :
- Applied optics
- Publication Type :
- Academic Journal
- Accession number :
- 20648167
- Full Text :
- https://doi.org/10.1364/AO.49.003922