Back to Search
Start Over
Quantitative analysis of coronary endothelial function with generator-produced 82Rb PET: comparison with 15O-labelled water PET.
- Source :
-
European journal of nuclear medicine and molecular imaging [Eur J Nucl Med Mol Imaging] 2010 Dec; Vol. 37 (12), pp. 2233-41. Date of Electronic Publication: 2010 Jul 13. - Publication Year :
- 2010
-
Abstract
- Purpose: Endothelial dysfunction is the earliest abnormality in the development of coronary atherosclerosis. 82Rb is a generator-produced positron emission tomography (PET) myocardial perfusion tracer that is becoming more widely used. We aimed to (1) develop a method for quantitative assessment of coronary endothelial function using the myocardial blood flow (MBF) response during a cold pressor test (CPT) in smokers, measured using 82Rb PET, and (2) compare the results with those measured using 15O-water PET.<br />Methods: MBF was assessed at rest and during the CPT with 82Rb and 15O-water in nine controls and ten smokers. A one-compartment model with tracer extraction correction was used to estimate MBF with both tracers. CPT response was calculated as the ratio of MBF during the CPT to MBF at rest.<br />Results: At rest, measurements of MBF for smokers vs controls were not different using 15O-water (0.86±0.18 vs 0.70±0.13, p=0.426) than they were using 82Rb (0.83±0.23 vs 0.62±0.20, p=0.051). Both methods showed a reduced CPT response in smokers vs controls (15O-water, 1.03±0.21 vs 1.42±0.29, p=0.006; 82Rb, 1.02±0.28 vs 1.70±0.52, p<0.001). There was high reliability [intraclass correlation coefficients: 0.48 (0.07, 0.75)] of MBF measurement between 82Rb and 15O-water during the CPT.<br />Conclusion: Using a CPT, 82Rb MBF measurements detected coronary endothelial dysfunctions in smokers. 82Rb MBF measurements were comparable to those made using the 15O-water approach. Thus, 82Rb PET may be applicable for risk assessments or evaluation of risk factor modification in subjects with coronary risk factors.
- Subjects :
- Adult
Female
Humans
Isotope Labeling
Male
Middle Aged
Radiopharmaceuticals
Reproducibility of Results
Sensitivity and Specificity
Water
Coronary Vessels diagnostic imaging
Endothelium, Vascular diagnostic imaging
Oxygen Radioisotopes
Positron-Emission Tomography methods
Rubidium Radioisotopes
Smoking
Subjects
Details
- Language :
- English
- ISSN :
- 1619-7089
- Volume :
- 37
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- European journal of nuclear medicine and molecular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 20625721
- Full Text :
- https://doi.org/10.1007/s00259-010-1541-y