Back to Search
Start Over
In vitro evaluation of gentamicin- and vancomycin-containing minitablets as a replacement for fortified eye drops.
- Source :
-
Drug development and industrial pharmacy [Drug Dev Ind Pharm] 2010 Nov; Vol. 36 (11), pp. 1259-70. - Publication Year :
- 2010
-
Abstract
- Objective: Ocular bioadhesive minitablets containing gentamicin and vancomycin were developed using different powder mixtures of pregelatinized starch and Carbopol (physical or cospray-dried mixtures).<br />Methods: Drug content, antimicrobial activity, and radical formation of the powders used for tablet preparation were evaluated immediately and 30 days after gamma sterilization. Tablet properties and in vitro drug release from the sterilized minitablets were determined. Storage stability of vancomycin and gentamicin in sterilized bioadhesive mixtures was examined by LC-UV/MS and a microbiological assay, respectively. A bioadhesive powder mixture containing only vancomycin was irradiated by X electron-magnetic radiation to evaluate vancomycin stability following sterilization through irradiation.<br />Results: The antimicrobial activity of gentamicin against Staphylococcus epidermidis was not altered in comparison to nonsterilized formulations. Only after an overkill dose of 50 kGy, the concentration of vancomycin decreases to an extent that was pharmaceutically significant. No significant difference in radiation stability between drug substance and product (i.e., powder mixture) was observed. A shift in stability profile was not observed at 6 weeks after irradiation. All other degradation products were present only in small quantities not exceeding 1.0%. The in vitro drug release from the minitablets prepared with physical powder mixtures of pregelatinized starch and Carbopol® 974P NF (96 : 4) was faster compared to the cospray-dried mixtures of starch with Carbopol® 974P NF (ratio: 95:5 and 85:15). The electron paramagnetic resonance signals of the radicals formed during sterilization were still visible after storage for 30 days. The slug mucosal irritation test indicated mild irritation properties of the bioadhesive powder mixtures although no tissue damage was observed.
- Subjects :
- Acrylic Resins
Adhesiveness
Animals
Anti-Bacterial Agents administration & dosage
Anti-Bacterial Agents toxicity
Drug Stability
Drug Storage
Gastropoda
Gentamicins administration & dosage
Gentamicins toxicity
Humans
Mucous Membrane drug effects
Polyvinyls chemistry
Staphylococcus epidermidis drug effects
Starch chemistry
Tablets
Toxicity Tests
Vancomycin administration & dosage
Vancomycin toxicity
Anti-Bacterial Agents pharmacology
Excipients chemistry
Gentamicins pharmacology
Vancomycin pharmacology
Subjects
Details
- Language :
- English
- ISSN :
- 1520-5762
- Volume :
- 36
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Drug development and industrial pharmacy
- Publication Type :
- Academic Journal
- Accession number :
- 20545514
- Full Text :