Back to Search
Start Over
Role of three-dimensional echocardiography in breast cancer: comparison with two-dimensional echocardiography, multiple-gated acquisition scans, and cardiac magnetic resonance imaging.
- Source :
-
Journal of clinical oncology : official journal of the American Society of Clinical Oncology [J Clin Oncol] 2010 Jul 20; Vol. 28 (21), pp. 3429-36. Date of Electronic Publication: 2010 Jun 07. - Publication Year :
- 2010
-
Abstract
- Purpose: In patients with breast cancer, the administration of doxorubicin and trastuzumab is associated with an increased risk of cardiotoxicity. Although multiple-gated acquisition (MUGA) scans and two-dimensional transthoracic echocardiography (TTE) are conventional methods for baseline and serial assessment of left ventricular ejection fraction (LVEF) in these patients, little is known about the use of real-time three-dimensional TTE (RT3D TTE) in this clinical setting. The aim of this study was to assess the accuracy of MUGA, 2D TTE, and RT3D TTE for determining LVEF in comparison to cardiac magnetic resonance imaging (CMR).<br />Methods: Between 2007 and 2009 inclusive, 50 female patients with human epidermal growth factor receptor 2-positive breast cancer received adjuvant trastuzumab after doxorubicin. Serial MUGA, 2D TTE, RT3D TTE, and CMR were performed at baseline, 6, and 12 months after the initiation of trastuzumab.<br />Results: A comparison of left ventricular end diastolic volume (LVEDV) demonstrated a modest correlation between 2D TTE and CMR (r = 0.64 at baseline; r = 0.69 at 12 months, respectively). A comparison of LVEDV between RT3D TTE and CMR demonstrated a stronger correlation (r = 0.87 at baseline; r = 0.95 at 12 months, respectively). Although 2D TTE demonstrated a weak correlation with CMR for LVEF assessment (r = 0.31 at baseline, r = 0.42 at 12 months, respectively), both RT3D TTE and MUGA showed a strong correlation when compared with CMR (r = 0.91 at baseline; r = 0.90 at 12 months, respectively).<br />Conclusion: As compared with conventional MUGA, RT3D TTE is a feasible, accurate, and reproducible alternate imaging modality for the serial monitoring of LVEF in patients with breast cancer.
Details
- Language :
- English
- ISSN :
- 1527-7755
- Volume :
- 28
- Issue :
- 21
- Database :
- MEDLINE
- Journal :
- Journal of clinical oncology : official journal of the American Society of Clinical Oncology
- Publication Type :
- Academic Journal
- Accession number :
- 20530277
- Full Text :
- https://doi.org/10.1200/JCO.2009.26.7294