Back to Search
Start Over
Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I.
- Source :
-
The Journal of prosthetic dentistry [J Prosthet Dent] 2010 Jun; Vol. 103 (6), pp. 334-42. - Publication Year :
- 2010
-
Abstract
- Statement of Problem: An optimal method for approaching the clinical surgical situation, when using preoperatively, virtually planned implant positioning, is to transfer data to a CAD/CAM-guided surgical template with the definitive position of the implant placed after surgery. The accuracy of CAD/CAM-guided surgeries must be determined to provide safe treatment.<br />Purpose: The purpose of this study was to compare the deviation between the position of virtually planned implants and the position of implants placed with a CAD/CAM-guided surgical template in the mandible and the maxilla in human cadavers.<br />Material and Methods: Ten maxillae and 7 mandibles, from completely edentulous cadavers, were scanned with CT, and 145 implants (Brånemark RP Groovy) were planned with software and placed with the aid of a CAD/CAM-guided surgical template. The preoperative CT scan was matched with the postoperative CT scan using voxel-based registration. The positions of the virtually planned implants were compared with the actual positions of the implants. Data were analyzed with a t test (alpha=.05).<br />Results: The mean measurement differences between the computer-planned implants and implants placed after surgery for all implants placed were 1.25 mm (95% CI: 1.13-1.36) for the apex, 1.06 mm (95% CI: 0.97-1.16) for the hex, 0.28 mm (95% CI: 0.18-0.38) for the depth deviation, 2.64 degrees (95% CI: 2.41-2.87) for the angular deviation, and 0.71 mm (95% CI: 0.61-0.81 mm) for the translation deviation.<br />Conclusions: The results demonstrated a statistically significant difference between mandibles and maxillae for the hex, apex, and depth measurements in the variation between the virtually planned implant positions and the positions of the implants placed after surgery with a CAD/CAM-guided surgical template.<br /> (Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.)
- Subjects :
- Cadaver
Humans
Imaging, Three-Dimensional
Jaw, Edentulous surgery
Mandible surgery
Maxilla surgery
Models, Anatomic
Models, Dental
Patient Care Planning
Radiography
Radiology Information Systems
Software
Statistics, Nonparametric
Computer-Aided Design
Dental Implantation, Endosseous methods
Jaw, Edentulous diagnostic imaging
Surgery, Computer-Assisted methods
User-Computer Interface
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6841
- Volume :
- 103
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- The Journal of prosthetic dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 20493322
- Full Text :
- https://doi.org/10.1016/S0022-3913(10)60072-8