Back to Search
Start Over
Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.
- Source :
-
BMC musculoskeletal disorders [BMC Musculoskelet Disord] 2010 May 21; Vol. 11, pp. 95. Date of Electronic Publication: 2010 May 21. - Publication Year :
- 2010
-
Abstract
- Background: Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model.<br />Methods: In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting.<br />Results: The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p <or= 0.011, torsion p <or= 0.015) but revealed similar performance under cyclic loading (p = 0.43). The Fence instrumentation with established bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p <or= 0.017). However, all contact Fence specimens survived the cyclic test, whereas all LC-DCP constructs failed early during torsion testing (p < 0.001). All failures occurred due to breakage of the screw heads.<br />Conclusions: Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.
- Subjects :
- Aged
Aged, 80 and over
Biomechanical Phenomena
Bone Plates standards
Bone Screws standards
Cadaver
Compressive Strength physiology
Diaphyses anatomy & histology
Diaphyses physiology
Diaphyses surgery
Equipment Failure
Equipment Failure Analysis methods
Female
Femur anatomy & histology
Femur physiology
Femur surgery
Fracture Fixation methods
Humans
Male
Middle Aged
Stress, Mechanical
Weight-Bearing physiology
Bone Plates trends
Bone Screws trends
Equipment Design methods
Fracture Fixation instrumentation
Fractures, Bone surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1471-2474
- Volume :
- 11
- Database :
- MEDLINE
- Journal :
- BMC musculoskeletal disorders
- Publication Type :
- Academic Journal
- Accession number :
- 20492707
- Full Text :
- https://doi.org/10.1186/1471-2474-11-95