Sensitivity of two noninvasive blood pressure measurement techniques compared to telemetry in cynomolgus monkeys and beagle dogs.
- Source :
-
Journal of pharmacological and toxicological methods [J Pharmacol Toxicol Methods] 2010 Jul-Aug; Vol. 62 (1), pp. 54-63. Date of Electronic Publication: 2010 May 08. - Publication Year :
- 2010
-
Abstract
- Introduction: Animals are commonly used in toxicological research for the evaluation of drug effects on the cardiovascular system. Accurate and reproducible determination of blood pressure (BP) in conscious, manually restrained monkeys and dogs is a challenge with current non-invasive cuff techniques. The High Definition Oscillometry (HDO) technique enables real time measurements with immediate visual feedback via PC screen on data validity. HDO measurements are considerably faster with a duration of approximately 8 to 15s than conventional cuff methods that can take several minutes.<br />Methods: HDO Memo Diagnostic Model Science and Cardell BP Monitor Model 9401 measurements were compared for accuracy and reliability with simultaneously recorded direct blood pressure data captured via radiotelemetry. Six monkeys and six dogs implanted with DSI PCT telemetry transmitters were used; BP data were collected by all methods under manual constraint and compared. Measurements were performed with HDO and Cardell in the presence of a BP lowering drug (hexamethonium bromide). Systolic, diastolic, mean arterial pressure, and pulse rate were determined before, during and following up to 10mg/kg hexamethonium administration via intravenous slow bolus injection.<br />Results: Drug induced hemodynamic changes could be detected in monkeys and dogs with the HDO method but only in dogs with the Cardell method. Correlation coefficients were generally higher for HDO versus Telemetry than Cardell versus Telemetry comparisons, indicating that this novel, non-invasive technique produces reliable blood pressure data and is able to detect drug-induced hemodynamic changes.<br />Discussion: HDO provides an alternative approach for invasive telemetry surgeries to obtain reliable hemodynamic data in animal models for cardiovascular research when invasive techniques are not warranted.<br /> (Copyright 2010 Elsevier Inc. All rights reserved.)
- Subjects :
- Animals
Antihypertensive Agents administration & dosage
Antihypertensive Agents pharmacology
Automation
Dogs
Dose-Response Relationship, Drug
Electrodes, Implanted veterinary
Female
Hexamethonium administration & dosage
Hexamethonium pharmacology
Macaca fascicularis
Male
Oscillometry
Blood Pressure drug effects
Blood Pressure Determination veterinary
Telemetry veterinary
Subjects
Details
- Language :
- English
- ISSN :
- 1873-488X
- Volume :
- 62
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of pharmacological and toxicological methods
- Publication Type :
- Academic Journal
- Accession number :
- 20435151
- Full Text :
- https://doi.org/10.1016/j.vascn.2010.04.005