Back to Search Start Over

Diffusion tensor imaging in a human PET/MR hybrid system.

Authors :
Boss A
Kolb A
Hofmann M
Bisdas S
Nägele T
Ernemann U
Stegger L
Rossi C
Schlemmer HP
Pfannenberg C
Reimold M
Claussen CD
Pichler BJ
Klose U
Source :
Investigative radiology [Invest Radiol] 2010 May; Vol. 45 (5), pp. 270-4.
Publication Year :
2010

Abstract

Purpose: The aim of this study was to test and demonstrate the feasibility of diffusion tensor imaging (DTI) with a hybrid positron emission tomography (PET)/magnetic resonance imaging system for simultaneous PET and magnetic resonance (MR) data acquisition.<br />Materials and Methods: All measurements were performed with a prototype hybrid PET/MR scanner dedicated for brain and head imaging. The PET scanner, which is inserted into a conventional 3.0-Tesla high field MR imager equipped with a transmit/receive birdcage head coil, consists of 192 block detectors with a matrix of 12 x 12 lutetium oxyorthosilicate scintillation crystals combined with MR-compatible 3 x 3 avalanche photodiode arrays. In 7 volunteers and 4 patients with brain tumors, DTI was performed during simultaneous PET data readout applying a diffusion weighted echo planar sequence (12 noncollinear directions, echo time (TE)/repetition time (TR) 98 ms/5300 ms, b-value 800 s/mm). Image quality and accuracy of DTI were assessed in comparison with DTI images acquired after removal of the PET insert.<br />Results: The diffusion images showed good image quality in all volunteers regardless of simultaneous PET data readout or after removal of the PET scanner; however, significantly (P < 0.01) stronger rim artifacts were found in fractional anisotropy images computed from DTI images recorded during simultaneous PET acquisition, demonstrating higher eddy-current effects. In region of interest analysis, no notable differences were found in the computation of the direction of the principal eigenvector (P > 0.05) and fractional anisotropy values (P > 0.05). In the assessment of pathologies, in all 4 patients PET and DTI provided important clinical information in addition to conventional magnetic resonance imaging.<br />Conclusion: Diffusion tensor imaging may be combined with simultaneous PET data acquisition, offering additional important morphologic and functional information for treatment planning in patients with brain tumors.

Details

Language :
English
ISSN :
1536-0210
Volume :
45
Issue :
5
Database :
MEDLINE
Journal :
Investigative radiology
Publication Type :
Academic Journal
Accession number :
20351651
Full Text :
https://doi.org/10.1097/RLI.0b013e3181dc3671