Back to Search Start Over

Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA.

Authors :
Baan J
Yong ZY
Koch KT
Henriques JP
Bouma BJ
de Hert SG
van der Meulen J
Tijssen JG
Piek JJ
de Mol BA
Source :
Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation [Neth Heart J] 2010 Jan; Vol. 18 (1), pp. 18-24.
Publication Year :
2010

Abstract

Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the CoreValve ReValving System was performed under general anaesthesia in 30 high-risk (surgical) patients with a symptomatic severe aortic valve stenosis.Results. The patients had a mean age of 80.5+/-7.7 years, a mean aortic valve area of 0.71+/-0.19 cm(2), a peak transvalvular aortic gradient of 79+/-25 mmHg, as measured with echo Doppler, a logistic EuroSCORE of 15+/-10% and a Society of Thoracic Surgeons (STS) score of 5.2+/-2.9%. Device success was achieved in all patients and acute procedural success in 27 patients (90%). In the surviving patients, there was in a reduction of the peak aortic pressure gradient from 76+/-24 mmHg to 22+/-7 mmHg (n=24, p<0.00001) 30 days after successful device implantation. At 30 days, major adverse cardiovascular and cerebral events had occurred in seven patients (23%). This included mortality in six patients (20%), of which one death was cardiovascular. The other five non-cardiovascular deaths involved two patients who died of an exacerbation of severe pre-existent pulmonary disease and three of infectious complications.Conclusions. Percutaneous aortic valve implantation was successfully performed in our centre in highrisk patients, with a 30-day mortality of 20%. When successful, marked haemodynamic improvement and relief of symptoms was achieved. (Neth Heart J 2010;18:18-24.).

Details

Language :
English
ISSN :
1876-6250
Volume :
18
Issue :
1
Database :
MEDLINE
Journal :
Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation
Publication Type :
Academic Journal
Accession number :
20111639