Back to Search
Start Over
Continuous glucose monitoring system in 72-hour glucose profile assessment in patients with end-stage renal disease on maintenance continuous ambulatory peritoneal dialysis.
- Source :
-
Medical science monitor : international medical journal of experimental and clinical research [Med Sci Monit] 2010 Feb; Vol. 16 (2), pp. CR75-83. - Publication Year :
- 2010
-
Abstract
- Background: Glucose has been the main osmole used in conventional peritoneal fluids (PDFs) since the beginning of continuous ambulatory peritoneal dialysis (CAPD). There is much concern regarding the possible risk to the good level of glycemia control lately observed. The aim of this study was to analyze, with the use of 72-hour continuous glucose monitoring system (CGMS), the influence of PDFs containing supra-physiological glucose concentrations on daily glucose profile in patients with end stage renal disease (ESRD) undergoing CAPD therapy.<br />Material/methods: There were 30 diabetic and non-diabetic patients on CAPD using conventional 1.36% or 2.27% glucose PDFs examined in the study, with a control group of 13 healthy volunteers. All participants underwent 72-hour CGMS and HbA1c evaluation. There was the whole area under the curve (AUC) of each 24-hour glucose profile and of glucose excursion above 90 mg/dl estimated.<br />Results: The high transport status appeared to significantly influence the mean maximum glucose value and its increment following peritoneal exchange (PE) in the study group and in a subgroup of diabetic patients, whereas in non-diabetics the mean 24-hour glucose concentration was importantly influenced. The percentage of glucose levels in the range above 90 mg/dl was significantly influenced by higher glucose concentration in the PDFs, as well as higher peritoneal transport status.<br />Conclusions: The outcomes indicate that dialysate glucose concentration, as well as type of peritoneal transport, influence the occurrence of persistent hyperglycemia state, and suggest that CAPD may predispose to appearance of glycemic disorders.
- Subjects :
- Biological Transport
Case-Control Studies
Circadian Rhythm
Female
Humans
Kidney Failure, Chronic physiopathology
Male
Middle Aged
Peritonitis blood
Peritonitis complications
Blood Glucose metabolism
Blood Glucose Self-Monitoring instrumentation
Kidney Failure, Chronic blood
Kidney Failure, Chronic therapy
Peritoneal Dialysis, Continuous Ambulatory
Subjects
Details
- Language :
- English
- ISSN :
- 1643-3750
- Volume :
- 16
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Medical science monitor : international medical journal of experimental and clinical research
- Publication Type :
- Academic Journal
- Accession number :
- 20110918