Back to Search Start Over

Validation of the INNO-LiPA HBV DR assay (version 2) in monitoring hepatitis B virus-infected patients receiving nucleoside analog treatment.

Authors :
Niesters HG
Zoulim F
Pichoud C
Buti M
Shapiro F
D'Heuvaert N
Celis L
Doutreloigne J
Sablon E
Source :
Antimicrobial agents and chemotherapy [Antimicrob Agents Chemother] 2010 Mar; Vol. 54 (3), pp. 1283-9. Date of Electronic Publication: 2010 Jan 11.
Publication Year :
2010

Abstract

Hepatitis B virus (HBV) antiviral drug resistance mutations prevent successful outcome of treatment and lead to worsening of liver disease. Detection of its emergence permits opportune treatment with alternative drugs. Unfortunately, the use of newly approved antivirals, including adefovir dipivoxil, emtricitabine, and telbivudine, is also associated with the development of drug resistance, albeit to a lesser extent than the use of lamivudine. The objectives of this work were to assess the performance characteristics (sensitivity and accuracy) of an updated drug resistance test, the INNO-LiPA HBV DR v2, which includes detection of mutations associated with lamivudine, adefovir, emtricitabine, and telbivudine resistance, and to compare the results with consensus sequencing of serum samples from patients treated with HBV antivirals. Diagnostic sensitivity, defined as detection of a positive amplification line on the line probe assay (LiPA) strip, was 94.8% (95% confidence interval [CI], 89.7 to 97.9) after initial testing, increasing to 96.3% (95% CI, 91.6 to 98.8) after repeat test 1 and to 100% (95% CI, 97.3 to 100.0) after repeat test 2. In diagnostic accuracy determinations, full concordance was observed between sequencing and LiPA for 77.0% of the codons tested (620/805 codons [95% CI, 74.0 to 79.9]), whereas LiPA and sequencing were partially concordant 22% of the time (177/805 codons). In 167 out of 177 cases, LiPA detected a wild-type/mutant mixture whereas sequencing detected only one of the two results. Performance testing of the new LiPA test, the INNO-LiPA HBV DR v2, showed convincing diagnostic sensitivity and accuracy. The ability of the test to detect mixed infections and minority viral populations associated with resistance to the current generation of antivirals, including adefovir, emtricitabine, and telbivudine, makes it a useful tool for HBV therapy monitoring.

Details

Language :
English
ISSN :
1098-6596
Volume :
54
Issue :
3
Database :
MEDLINE
Journal :
Antimicrobial agents and chemotherapy
Publication Type :
Academic Journal
Accession number :
20065049
Full Text :
https://doi.org/10.1128/AAC.00970-09