Stent graft closure of a high flow splenorenal shunt after liver transplantation.
- Source :
-
Diagnostic and interventional radiology (Ankara, Turkey) [Diagn Interv Radiol] 2010 Dec; Vol. 16 (4), pp. 312-4. Date of Electronic Publication: 2009 Sep 25. - Publication Year :
- 2010
-
Abstract
- We describe a patient after liver transplantation with a preexisting surgical splenorenal shunt close to the confluence of the splenic and superior mesenteric veins and a wide, short communication between the splenic and renal veins. To close the shunt, an inferior vena cava filter was inserted in the shunt and a vascular plug was placed in the splenic vein inside the filter. When this failed to stop the flow through the shunt, a covered stent was deployed at the superior mesenteric vein-portal vein junction.
- Subjects :
- Adult
Contrast Media
Female
Follow-Up Studies
Humans
Radiographic Image Enhancement
Renal Veins diagnostic imaging
Renal Veins surgery
Splenic Vein diagnostic imaging
Splenic Vein surgery
Splenomegaly diagnostic imaging
Tomography, X-Ray Computed
Treatment Outcome
Ultrasonography, Doppler, Color
Vena Cava Filters
Liver Transplantation
Splenorenal Shunt, Surgical
Stents