3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T.
- Source :
-
Magnetic resonance imaging [Magn Reson Imaging] 2009 Nov; Vol. 27 (9), pp. 1249-57. Date of Electronic Publication: 2009 Sep 19. - Publication Year :
- 2009
-
Abstract
- Purpose: The goal of this study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques.<br />Methods: The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (e-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods.<br />Results: The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P<.05 for SENSE and P<.001 for e-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and e-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE k-space samplings were estimated to have a 2.36-2.47-fold loss in spatial resolution due to the differences in their point spread functions.<br />Conclusion: The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA.
- Subjects :
- Adult
Aged
Brain Neoplasms pathology
Female
Glioma pathology
Humans
Image Processing, Computer-Assisted
Lipids chemistry
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Whole Body Imaging
Brain Neoplasms diagnosis
Glioma diagnosis
Imaging, Three-Dimensional methods
Magnetic Resonance Spectroscopy methods
Subjects
Details
- Language :
- English
- ISSN :
- 1873-5894
- Volume :
- 27
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Magnetic resonance imaging
- Publication Type :
- Academic Journal
- Accession number :
- 19766422
- Full Text :
- https://doi.org/10.1016/j.mri.2009.05.028