Back to Search
Start Over
Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents.
- Source :
-
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology [EuroIntervention] 2009 Sep; Vol. 5 (4), pp. 505-10. - Publication Year :
- 2009
-
Abstract
- Aims: Biodegradable coatings on drug-eluting stents (DES) may help to avoid adverse long-term effects of DES such as late/very late stent thrombosis which is partly attributed to durable polymers. As the post-expansion morphology of biodegradable coatings is greatly unknown, we investigated the polylactic acid coating on biolimus-eluting BioMatrix stents.<br />Methods and Results: Scanning electron microscopy (SEM) was used to carefully examine five 3.5mm stents following expansion at 6-14atm (maximum 7% overstretch). SEM examination demonstrated only mild cracks of the coating after stent expansion at 6 atm. An increase in expansion pressure, associated with mild stent overstretch, resulted in more severe cracks. Lifting of the coating together with few sites of partial detachment of fragments was noticed after stent expansion in water at 14atm; these irregularities further increased after aggressive oversized partial postdilatation with a 5.0mm non-compliant balloon with additional secondary cracks.<br />Conclusions: SEM assessment suggests a relatively low elasticity of the biodegradable coating on BioMatrix stents. At nominal pressure, stents showed predominantly mild cracks of the coating, while cracks increased after slight overstretch. Aggressive overexpansion of the stent, such as sometimes required in left main bifurcation stenting, worsened cracks and led to some detachment of fragments of the coating in vitro.
- Subjects :
- Biosensing Techniques instrumentation
Biosensing Techniques methods
Equipment Design
Humans
Immunosuppressive Agents administration & dosage
Immunosuppressive Agents therapeutic use
Microscopy, Electron, Scanning methods
Reproducibility of Results
Sirolimus administration & dosage
Sirolimus analogs & derivatives
Sirolimus therapeutic use
Water
Absorbable Implants statistics & numerical data
Drug-Eluting Stents statistics & numerical data
Subjects
Details
- Language :
- English
- ISSN :
- 1774-024X
- Volume :
- 5
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 19755341
- Full Text :
- https://doi.org/10.4244/eijv5i4a80