Back to Search
Start Over
The use of flat panel angioCT (DynaCT) for navigation through a deformed and fractured carotid stent.
- Source :
-
Neuroradiology [Neuroradiology] 2010 Jul; Vol. 52 (7), pp. 629-32. Date of Electronic Publication: 2009 Jul 28. - Publication Year :
- 2010
-
Abstract
- Navigation through a previously deployed and deformed stent is a difficult interventional task. Inadvertent navigation through the struts of a stent can potentially lead to incomplete secondary stent extension and vessel occlusion. Better visualisation of the pathway through the stent can reduce the risks of the procedural complications and reduce the reluctance of the interventionalist to navigate through a previously deployed stent. We describe a technique of visualisation of the pathway navigated by a guidewire through a previously deployed deformed and fractured carotid stent by the use of DynaCT. Three-dimensional reconstruction of the stent/microwire allows excellent visualisation of the correct pathway of the microwire within the stent.
- Subjects :
- Aged
Carotid Stenosis diagnostic imaging
Carotid Stenosis surgery
Cerebral Angiography instrumentation
Endarterectomy, Carotid methods
Feasibility Studies
Follow-Up Studies
Humans
Imaging, Three-Dimensional
Magnetic Resonance Angiography
Male
Tomography, X-Ray Computed instrumentation
Treatment Outcome
Carotid Arteries diagnostic imaging
Carotid Arteries surgery
Cerebral Angiography methods
Prosthesis Failure
Stents
Tomography, X-Ray Computed methods
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1920
- Volume :
- 52
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Neuroradiology
- Publication Type :
- Academic Journal
- Accession number :
- 19636548
- Full Text :
- https://doi.org/10.1007/s00234-009-0556-1